Key Specs

Standby Rating
13.6/15.5/17.6/20 ekW
13.6/15.5/17.6/20 ekW
Prime Power Rating
12.4/14/16/18 ekw
12.4/14/16/18 ekw
Emissions/Fuel Strategy
EU Stage IIIA
EU Stage IIIA

Features At A Glance

Displaying 1-6 of 8

Cat

Cat Generator Set Package

        
  • Cat generator set packages have been fully prototype tested
  •     
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  •     
  • Conform to ISO 8528-5 steady state and transient response requirements
Cat

Cat Diesel Engine

        
  • Reliable, rugged, durable design
  •     
  • Field-proven in thousands of applications worldwide
  •     
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
Cat

M-Frame Alternator

        
  • Superior motor starting capability minimizes need for oversizing alternator
  •     
  • Designed to match performance and output characteristics of Cat diesel engines
  •     
  • Robust Class H insulation
Cat

GCCP 1.3 Control Panel

        
  • User-friendly interface and navigation
  •     
  • Scalable system to meet a wide range of installation requirement
  •     
  • Expansion modules and site-specific programming for specific customer requirements
  •     
  • Image may not be a representative of actual product
Cat

Cooling System

        
  • Designed to operate in standard ambient temperatures up to 55°C (131°F)
  •     
  • Contact your Cat Dealer for specific ambient and altitude capabilities
Cat

Certifications

Cat Dealers provide extensive post sale support including maintenance and repair agreements. Cat dealers have over 1,800 dealer branch stores operating in 200 countries. The Cat® SOSSM program cost effectively detects internal engine component condition, even the presence of unwanted fluids and combustion by-products.

Product Specifications for C2.2 (60 Hz)

Standby Rating 13.6/15.5/17.6/20 ekW 13.6/15.5/17.6/20 ekW
Prime Power Rating 12.4/14/16/18 ekw 12.4/14/16/18 ekw
Emissions/Fuel Strategy EU Stage IIIA EU Stage IIIA
Voltage 110 to 415 Volts 110 to 415 Volts
Frequency 60 Hz 60 Hz
Speed 1800 rpm 1800 rpm
Duty Cycle Standby, Prime Standby, Prime
Engine Model Cat® C2.2, In-line 4, 4-cycle diesel Cat® C2.2, In-line 4, 4-cycle diesel
Bore 3.3 in 84 mm
Stroke 3.9 in 100 mm
Displacement 135.2 in³ 2.2 l
Compression Ratio 22.5:1 22.5:1
Aspiration Naturally Aspirated Naturally Aspirated
Fuel System Indirect Injection Indirect Injection
Governor Type Mechanical Mechanical
Length - Maximum 59.1 in 1500 mm
Width - Maximum 24.4 in 620 mm
Height - Maximum 43.9 in 1115 mm

C2.2 (60 Hz) Standard Equipment

Air Inlet System

  • Air cleaner; light duty with disposable element

Control Panel

  • GCCP 1.3

Cooling System

  • Radiator and cooling fan with guards
  • Fan drive, battery charging alternator drive
  • Caterpillar extended life coolant
  • Coolant drain line with valve

Exhaust System

  • Stub pipe, gaskets, raincap & SAE exhaust flange for customer use - shipped loose

Fuel System

  • Standard open set fuel tank/base supplied
  • Base, formed steel with single wall integral 8-hour fuel tank

Generators and Generator Attachments

  • IP23 Protection
  • Circuit breaker, IEC, 3 pole, mounted in tower panel
  • 12 Leads
  • Segregated low voltage (AC/DC) wiring panel
  • Voltage regulator (single phase sensing)
  • Tower panel, IP22, bottom cable entry

Governing System

  • Mechanical governing system

Lube System

  • Oil drain line with valve
  • Lubricating oil

Mounting System

  • Captive linear vibration isolators between base and engine-generator
  • Includes lifting provisions and termination points for coolant

Starting / Charging System

  • 12 Volt battery with rack and cables

General

  • Engine and alternator pre-paint, Caterpillar yellow

C2.2 (60 Hz) Optional Equipment

Alternator Options

  • Coastal insulation protection

Certificates

  • Global certification for CIS
  • European upgrade to STD set for CE certificate

Circuit breakers

  • 4 Pole Circuit breaker
  • Padlockable breaker device

Control Panel Options

  • Volt free contacts for common alarm
  • Battery charger
  • Volt free contacts for genset running
  • Emergency stop with key
  • GCCP 1.3

Cooling System

  • Coolant heater

Enclosures

  • Aluminium
  • Steel
  • Single point lift for enclosure
  • Sound attenuated enclosure (GALV)

Fuel System

  • Skidbase for enclosures
  • DEFRA bunded fuel tank
  • Skidbase for open sets
  • Base feet
  • 1000 Hr extended service interval
  • Low fuel level alarm

Mounting Options

  • Battery removal
  • Industrial silencer removal
  • Silencer installation kit

Special Test and Inspection

  • PGS Test report @ 1.0 power factor

General

  • Packing case - canopied set
  • Radiator stone guard
  • Packing case - compact set

See how C2.2 (60 Hz) compares against frequently compared products.

Service Agreement (Cat® CVA & LTSA)

Experience hassle-free ownership and predictable expenses with flexible Customer Value Agreements, which include Long-Term Service Agreements.

Learn More

Parts

Shop for genuine and Cat Reman parts online, with access to price, inventory, and 24/7 expert support.

Learn More

Maintenance and Repairs

Retain genset value with maintenance, upgrade kits, and repair options that extend lifecycles, optimise performance, and help you control costs.

Learn More

Cat RAM and Condition Monitoring

Observe and manage your fleet from anywhere with Cat RAM, and benefit from real-time monitoring by expert advisors with Condition Monitoring.

Learn More

Media Gallery

C2.2 Generator Set Rear Right

C2.2 Generator Set Rear Left

C2.2 Generator Set Left Right

C2.2 Generator Set Front Left

Enclosure

Encosure

C2.2 Generator Set Rear Right
C2.2 Generator Set Rear Left
C2.2 Generator Set Left Right
C2.2 Generator Set Front Left
Enclosure
Encosure

360 View
360 View